Halcon  >  AI - Page Sitemap  >  energy-saving retrofit lights suppliers for office
energy-saving retrofit lights suppliers for office

energy-saving retrofit lights suppliers for office
  • energy-saving retrofit lights suppliers for office

energy-saving retrofit lights suppliers for office

There are many factors influence the design of Halcon retrofit lights. They are size, weight, required motion, labor required, speed of operation, etc.
Inquire Online
Get the latest price
Quantity Needed:
Pieces
E-mail:


  • ■ CONSTRUCTION
    Die formed of 0.6mm cold-rolled steel body
    All steel surface are painted after fabrication with high gloss backed white matte powder painted.
    High-diffusion light-milky PC diffuser
    Fully recessed luminaire fits standard T-Grid ceilings.

  • ■ LABELS
    CE & ETL Listed, approved for dry/damp location unless otherwise noted

  • ■ ELECTRICAL
    All electrical components are UL approved, Input Voltage from 100-277V
    Bridgelux SMD2835 LED chips
    120-277V UL/CUL 0-10V LED Driver
    5 years Warranty

  • ■ OPTIONS
    1-Available for dimmable version
    2-Available for emergency version
    3-Available for installing with sensor

Product features
  •     ETL & DLC listed; With LM79 & LM80;

  •     2'x2':27W,36W / 2'x4': 40W,50W / 1'x4': 40W

  •     High luminous efficacy 125 lm/w;

  •     50,000 hours warranty 0-10V UL/CUL listed LED Driver, Flicking free.

  •     PF>0.90

  •    driver efficiency>87%;THD<20%;                    

  •      Installation:  chain mounting

  •    Suitablefor dry/damp location;

  •    Designed for office, conference room

  •    CCT: 4000K & 5000K;

  •    Lifetime: 5 years

Product dimension


energy-saving retrofit lights suppliers for office-1
Model    NoAWatts
HG-L254/DM-XY23.8"23.8"3.15"27W
HG-L254/DM-X 23.8"23.8"3.15"36W
HG-L254/DM-XX47.6"12.8"3.15"40W
HG-L254/DM-XXY47.6"23.8"3.1540W
HG-L254/DM-XXX47.6"23.8"3.1550W
Technical data
energy-saving retrofit lights suppliers for office-2
Total    Input Watt 27W36W40W40W50W
Size2'x2'2'x2'1'x4'2'x4'2'x4'
Calculated    L70 50,000 hrs
Delivered    Lumens 3375 lm4500 lm5000 lm5000 lm6250 lm
Luminaire    Efficacy Rating  125 LM/W
Correlated    Color Temperature  3000K,4000K,5000K
Color    Rendering Index  >80
Light distribution
energy-saving retrofit lights suppliers for office-3
energy-saving retrofit lights suppliers for office-4
Installation
INSTALLATION FOR RECESSED
energy-saving retrofit lights suppliers for office-5

1-Drill the holes in the wooden ceiling.

energy-saving retrofit lights suppliers for office-6

2-Turn off the power,make the wire connection to the quick connector.

energy-saving retrofit lights suppliers for office-7

3-Turn the light into the opening ceiling.

energy-saving retrofit lights suppliers for office-8

4-Make sure the light sitting down well to the ceiling frame.

energy-saving retrofit lights suppliers for office-9

5-The lights sit well on the ceiling frame.

energy-saving retrofit lights suppliers for office-10

6-The wire connection diagram

INSTALLATION FOR HANGING
energy-saving retrofit lights suppliers for office-11

1-Drill the holes in the wooden ceiling;
And install the hanging ring into the ceiling.

energy-saving retrofit lights suppliers for office-12

2-Use a screwdriver to straighten the hanging tabs.

energy-saving retrofit lights suppliers for office-13

3-Install the Hook or stainless coabe into the hanging tab.

energy-saving retrofit lights suppliers for office-14

4-Lock the chain/stainess wire into the installed ring or mounting bracket.

energy-saving retrofit lights suppliers for office-15

5-Turn off the power,make the wire connection to the quick connector.

energy-saving retrofit lights suppliers for office-16
Warning
1
1
The installation and maintenance must be completed by electricians or professionals.
1
1
Please cut off the power before installation and maintenance.
1
1
The thermally insulating material is not allowed to cover the fixture.
1
1
Pleasekeepawayfromthecorrosivesubstance,andkeepthefixturedryandclean.
1
1
Working temperature: -4°F~104°F, storage temperature: -22°F~140°F.
Applications
energy-saving retrofit lights suppliers for office-17
Office
energy-saving retrofit lights suppliers for office-18
Conference Room



Halcon retrofit lights is designed with consideration of all possible mechanisms. These mechanisms are aimed at helping the desired motion or the group of motions in this product.
Halcon retrofit lights is strictly assessed after production. Many factors include part tolerances, size limitations, materials properties, mechanical analysis, and function realization have been analyzed.
The creation of Halcon retrofit lights involves some advanced technologies. They include mechanical systems technology, automatic control technology, sensing technology, and servo-drive technology.
There are many factors being considered while designing Halcon retrofit lights. They are the selection of materials, modes of loading, safety factors, allowable stresses, etc.
The design of Halcon retrofit lights requires many skills. Except for basic knowledge such as Kinematics and Mechanisms, they also include Technical Drawing and Computer-Aided Engineering (CAE).
This product is more powerful than the traditional one and is easy to use.
Product Message
Chat Online 编辑模式下无法使用
Chat Online inputting...